15/18
Bosch Rexroth Canada ı 07.22.2013 ı Revision 2.0
11 Spinner Reverse Mode
Click the “R” button of spinner knob on the screen to control spinner forward or
reverse.
When the “R” button is pressed the controller would ramp down the spinner from
the speed selected and ramp up to the opposite direction to the speed selected.
12 Error Codes
ERROR BLAST TOO LONG 1 Turn off blast, reset timer
ERROR DEICE BLST TOO LONG 2 Turn off blast, reset timer
ERROR OVERSPEED 3 Slow down, reset max speed
ERROR SPIN PROP 4 Check cables, replace coil
ERROR CONV PROP 5 Check cables, replace coil
ERROR CROSS1 PROP 6 Check cables, replace coil
ERROR CROSS2 PROP 7 Check cables, replace coil
ERROR NO MATL DETECT 8 Load material, check sensor
ERROR NO LIQ DETECT 9 Load material, check sensor
ERROR NO GROUNDSPEED 10 Check cable/sensor
ERROR NO CONVEYOR 11 Check cable/sensor
ERROR NO LIQUID 12 Check cable/sensor
ERROR NO DEICE 13 Check cable/sensor