D1260/D1260B | Installation Guide | 2.0 D1260/D1260B Overview
8 Bosch Security Systems | 9/04 | 48101E
2.3 Internal Features
To access the inside of the D1260/D1260B, the back plate must be removed. Using a small flat-blade screwdriver,
gently push in the two holes in the bottom of the D1260/D1260B. As the tabs are pushed in, lift the back plate
away from the rest of the unit.
Figure 4: D1260/D1260B with Back Plate Removed
ON CTS
123456
1
2
4
5
3
1 - DIP switch (Six-position) - allows you to select the
address of each keypad, and enable/ disable the
keypad encoding tone.
(refer to Section 3.2 Setting the DIP Switch on
page 10).
2 - EEPROM socket (with example EEPROM
installed)
3 - Volume control potentiometer
(refer to Section 3.4 Volume Control on
page 10)
4 - Wall tamper switch
(refer to Section 3.3 Tamper Switch on
page 10)
5- SDI connector jack