4.0 Installation
4.1 Installation Preparation
This section contains a general installation procedure
and refers to other sections of the document for
detailed instructions.
Review this document and the D7212GV2 Program
Entry Guide (P/N: F01U003804) before beginning the
installation to determine the hardware and wiring
requirements for the features used.
Have the following documentation available when
reading through this guide:
•
D7212GV2 Program Record Sheet (P/N:
F01U003803)
•
Security System Owner’s Manual (P/N: 71-06633-000)
and Security System Owner’s Manual Supplement
(P/N: 33267)
• Command center (keypad) installation manual
(D1255, D1256, D1257, D1260, or D720)
Before installation, become familiar with the operation
of the D5200 Programmer or the RPS.
4.2 Enclosure Options
Mount the control panel assembly in any of the Bosch
Security Systems enclosures listed:
• D8103 Universal Enclosure (tan)
• D8108A Attack Resistant Enclosure (tan)
Refer to the D7212GV2 Approved Applications Compliance
Guide (P/N: F01U003806) to determine if the
application requires a specific enclosure.
4.3 Mounting Enclosure
1. Run the necessary wiring throughout the premises.
2. Mount the enclosure in the desired location. Use
all five enclosure mounting holes. Refer to Figure 2.
3. Pull the wires into the enclosure.
Electro-Magnetic Interference (EMI) can cause
problems on long wire runs. Refer to EMI on Long Wire
Runs in the D9412GV2/D7412GV2/D7212GV2
Installation and Troubleshooting Quick Reference Guide
(P/N: F01U003638).
Figure 2: Enclosure Mounting
8
2
1
3
2
4
3
7
5
9
6
1 - Point chart label
2 - Mounting skirt hooks (2)
3 - Module mounting holes (12)
4 - Tamper switch mounting holes (5)
5 - Skirt mounting hole (1)
6- Enclosure mounting holes (5)
7 - Mounting skirt hook holes (2)
8 - Back of D7212GV2 Control Panel
9 - Lock down tab