EasyManuals Logo

Bosch GLM 30 Operating/Safety Instructions

Bosch GLM 30
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
-12-
Note:
The measured value typically appears within 0.5 seconds
and no later than 4 seconds. The duration of the measurement
depends on the distance, the lighting conditions and the
reflective properties of the target surface. Upon completion of the
measurement the laser beam is automatically switched off.
Measuring Functions
Real Time Measurement
For real time measurements, the measuring tool can be moved
relative to the target, whereby the measuring value is updated
approx. every 0.5 seconds. In this manner for example, the
distance displayed on the screen will change in real time as you
move further or closer to the measured target.
For real time measurements, repeatedly press button
4
until
the indicator for real time measurement appears on the display
1
. Press Measure button
2
to activate laser. The laser will be
switched on and measuring will begin immediately.
Move the measuring tool until the required
distance value is indicated in the bottom of the
display.
Press the measuring button
2
to hold the
measurement. The held measurement will
display at the bottom of the display.
Press the measuring button
2
to reactivate real time measuring
on the bottom line and the held measurement will move to the
middle line.
Press the measuring button
2
to hold the measurement on
the bottom line. The held measurement on the middle line will
continue to hold.
Press the measuring button
2
to reactivate real time measuring
on the bottom line and the previous held real time will move to
the middle and top lines.
Press the measuring button
2
to hold the measurement on the
bottom line. The last three measurements will now be held and
displayed on the bottom, middle, and top lines.
Real time measurement automatically switches off after 5
minutes. The last measured value remains indicated at the
bottom on the display.

Other manuals for Bosch GLM 30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch GLM 30 and is the answer not in the manual?

Bosch GLM 30 Specifications

General IconGeneral
Accuracy± 2 mm
Laser Class2
Laser Type635 nm, <1 mW
Power Supply2 x 1.5 V LR03 (AAA)
Dimensions105 x 41 x 24 mm
Measurement Time, typical0.5 s
Measurement Time, max.4 s
Automatic Deactivation5 min
Operating Temperature-10 – 50 °C
Protection ClassIP54
Measurement Range0.15 – 30 m
Units of Measurementm
Battery Life5000 individual measurements
DisplayIlluminated display

Related product manuals