Page #5 background imageLoading...
Page #5 background image
-5-
General Safety Rules
!
WARNING
Read all instructions. Failure to follow all
instructions listed below may result in
hazardous radiation exposure, electric shock, fire and/or
serious injury.
The term “tool” in the warnings listed below
refers to your mains-operated (corded) tool or battery-operated
(cordless) tool.
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE
The following label is on your laser
tool for your safety. ALWAYS BE
AWARE of its location when using
the tool.
DO NOT direct the
laser beam at persons
or animals and do not
stare into the laser beam yourself. This tool
produces class 2 laser radiation and complies
with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to Laser Notice No. 50, dated June 24, 2007. This
can lead to persons being blinded.
Safety Rules
Working safely with the
measuring tool is possible
only when the operating
and safety information
are read completely and
the instructions contained
therin are strictly followed.
Never make warning labels
on the Measuring tool
unrecognizable.
Never aim the beam at a
workpiece with a reflective
surface. Bright shiny
reflective sheet steel or
similar reflective surfaces are
not recommended for laser
use.
Reflective surfaces could
direct the beam back towards the
operator.
Take care to recognize the
accuracy and range of the
device.
Measurement may not
be accurate if used beyond the
rated range of the device.
Use of controls or
adjustments or performance
of procedures other than
those specified herein may

Other manuals for Bosch GLM 30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch GLM 30 and is the answer not in the manual?

Bosch GLM 30 Specifications

General IconGeneral
Accuracy± 2 mm
Laser Class2
Laser Type635 nm, <1 mW
Power Supply2 x 1.5 V LR03 (AAA)
Dimensions105 x 41 x 24 mm
Measurement Time, typical0.5 s
Measurement Time, max.4 s
Automatic Deactivation5 min
Operating Temperature-10 – 50 °C
Protection ClassIP54
Measurement Range0.15 – 30 m
Units of Measurementm
Battery Life5000 individual measurements
DisplayIlluminated display