EasyManua.ls Logo

Bosch GLM 80 - Indirect Measurement Techniques; Methods for Indirect Distance Measurement

Bosch GLM 80
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
For continuous measurements,
press function mode button 4 until
the indicator for continuous
measurement appears on the
display. To start the continuous
measurement, press the
measuring button 2.
The minimum measurement is
used to determine the shortest
distance from a fixed reference
point. It is used, as an example, for
determining plumb lines or
horizontal partitions.
The maximum measurement is
used to determine the greatest
distance from a fixed reference
point. It is used, as an example, for
determining diagonals.
The current
measuring value is
displayed in the
result line c. The
maximal (“max”)
and the minimal
(“min”) measuring value are
displayed in the measured value
lines a.
It is always overwritten,when the
current length measurement value
is less than the present minimal or
larger than the present maximal
value.
The previous minimal and
maximal values are deleted by
pressing the button for clearing the
internal memory 8.
Pressing the measuring button 2
ends the continuous
measurement. The last measured
value is displayed in the result line
c.
Pressing the measuring button 2
again restarts a continuous
measuring run.
Continuous measurement
automatically switches off after 5
min. The last measured value
remains indicated in the result line
c.
Indirect Distance Measurement
The indirect distance
measurement is used to measure
distances that cannot be
measured directly because an
obstacle would obstruct the laser
beam or no target surface is
available as a reflector. This
measuring procedure can only be
used in vertical direction. Any
deviation in horizontal direction
leads to measuring errors.
The laser beam remains switched
on between the individual
measurements.
For indirect length measurements,
three measuring modes are
available. Each measuring mode
can be used for determining
different distances.
a) Indirect height measurement
(see figure C)
Press the function-mode button 4
until the indication for indirect
height measurement appears
on the display.
Pay attention that the measuring
tool is positioned at the same
height as the bottom measuring
point. Now, tilt the measuring tool
1
-24-

Other manuals for Bosch GLM 80

Related product manuals