10 TROUBLESHOOTING
The information in this section will be helpful when troubleshooting, diagnosing, and resolving faults and other issues affecting the normal operation
of the oven in the range. Please refer to the cooktop Failure Codes and Service Programs in QuickFinder.
10.1 Error Codes
A Service Guide/Wire Diagram that includes error code information is available in QuickFinder and is also packed with
every range. Separate diagrams for the induction cooktops are also packed with each range. Find them in a pouch taped
to the rear vented panel, as shown in Figure 33.
Additional error code information and suggested repair actions can be found in the following table. Note that error codes
which begin with E1 apply specifically to the oven cavity, and those which begin with E2 apply specifically to the
warming drawer.
Error
Code
Description Cause/Notes Suggested Action(s)
E000
Wrong module code
(E100/E400 internal errors
reported as E000)
Control module and user interface are
mismatched. No operation is possible.
Enter correct option code in Service mode.
E302 Control module too hot
Temperature sensor on the control module
detects temperature higher than limit value.
Control turns off heating elements and fan
defaults to high speed. When cavity
temperature lowers to 212°F/100°C, heating
will resume and error will be cleared. (If self-
clean was running, it will be disabled until a
control reset is performed.)
If cooling fan is not operating…
Check connections to the fan and the
control module (see Small Load Schematic).
If cooling fan is operating…
Check element operation
Check for air obstruction or damaged
upper/lower ventilation trims
Check for stuck relays.