Technical
terms
Child
lock
Settings
in
the
standard
display
and
in
the
menu
can
only
be
changed
if
the
child
lock
(key
lock)
is
switched
off
(~page
12)
.
COOLING
A
heat
pump
can
both
emit
and
absorb
heat.
It
is
therefore
possible
to
cool
the
water
in
the
heating
system.
If
the
room
temperature
rises
above
a
certain
value.
it
is
maintained
at
the
set
value
in
cooling
mode.
Idle
When
the
system
is
idle
.
neither
heating
nor
cooling
takes
place
.
This
status
can
occur
between
the
heating
and
cooling
modes.
The
heat
pump
remains
switched
on.
however.
Mixer
Assembly
that
automatically
ensures
that
hot
water
can
be
drawn
from
the
taps
at
a
temperature
no
higher
than
the
temperature
set
on
the
mixer.
Optimised
operation
In
optimised
operation.
automatic
mode
(the
heating
system
time
program)
is
not
active
and
the
home
is
heated
constantly
to
the
temperature
set
for
optimised
operation
.
Reference
room
The
reference
room
is
the
room
in
the
home
where
a
room
unit
has
been
installed.
The
room
temperature
in
this
room
acts
as
the
control
variable
for
the
assigned
heating
circuit.
Switching
time
A
certain
time
at
which
the
heating
system
starts
to
heat
or
hot
water
is
produced.
for
example.
A
switching
time
is
a
component
of
a
time
program.
Smart
grid
In
a
smart
grid
.
power
generators
and
loads
are
linked
and
can
communicate
with
each
other
in
an
electricity
grid
.
This
additional
networking
allows
output
peaks
and
idle
times
to
be
avoided
more
effectively
by
switching
the
loads
on
and
off
as
necessary
to
optimise
grid
utilisation
.
Temperature
of
an
operating
mode
A
temperature
that
is
assigned
to
an
operating
mode.
The
temperature
is
adjustable
.
See
the
explanations
on
operating
mode.
Thermal
disinfection
This
function
heats
up
the
hot
water
to
a
temperature
in
excess
of
65
·C.
This
temperature
is
sufficient
to
kill
off
pathogens
(e.g.legionella)
.
Observe
the
anti-scalding
safety
instructions
.
BOSCH
Holiday
program
The
holiday
program
enables
the
settings
that
would
ordinarily
be
applied
to
be
interrupted
for
a
number
of
days.
After
the
end
of
the
holiday
program.
the
programming
unit
resumes
operation
with
the
settings
that
would
ordinarily
be
applied
.
Flow
temperature
Temperature
at
which
the
heated
water
flows
in
the
central
heating
system
from
the
heat
source
to
the
heating
surfaces
in
the
rooms
.
Water
heater
A
water
heater
stores
large
volumes
of
heated
tap
DHW
.
Thereby.
sufficient
DHW
is
available
at
the
draw-off
points
(e.g
.
taps)
.
This
is
a
prerequisite
for
longer
hot
shower.
Time
program
for
the
heating
system
This
time
program
ensures
automatic
changeover
between
operating
modes
at
defined
switching
times.
Time
program
for
hot
water
heating
This
time
program
means
that
the
system
automatically
switches
between
the
modes
DHW
.
DHW
reduced
and
Off
at
fixed
break
points
. It
can
be
connected
to
the
time
program
for
house
heating
(~
chapter
5_
3.2.
page
21)
_
Time
program
for
circulation
This
time
program
ensures
automatic
operation
of
the
DHW
circulation
pump
at
defined
switching
times.
Linking
this
time
program
to
the
time
program
for
hot
water
is
recommended
.
Hot
water
circulation
pump
A
hot
water
circulation
pump
allows
the
hot
water
to
circulate
between
the
hot
water
heater
and
the
taps.
In
this
way
you
have
quick
assess
to
hot
water
at
the
taps
.
The
circulation
pump
can
be
controlled
with
a
time
program
.
42
HPC400
- 6 720821983 (2017/07)
9
BOSCH
Notes
HPC400-672082
1983(2017/07)
43