ICP-CC488 | User's Guide | 3. Codepad Indicators EN | 6
Bosch Security Systems, Inc. | 12/08 | F01U089456-02
Figure 4: ICP-CP516 Sixteen Zone LED
Codepad
The codepad is the communications interface
between you and your alarm system. Use the
codepad to issue commands. The codepad offers
both visual and audible indications that guide you
through the general operation.
The codepad incorporates numerous indicators.
There are zone indicators used to show the condition
of each zone. Four other indicators show general
status. The following pages outline a list of situations
and the relevant indicators that are seen.
The ICP-CP516 Sixteen Zone Codepad must be used
with sixteen wireless zone systems. The sixteen zone
codepads operation and display similarly to 8 zones
codepads, but also display the zones 9 through 16.
3.1 Zone Indicators
1 2 3 ….
The zone indicators (1 to 8) display
the status of the zones. Table 2 lists the
various circumstances that the
indicators display (such as Zone
Sealed, Zone Unsealed, and so on).
Table 2: Zone Indicators
Indicator Definition
On Zone is unsealed.
Off Zone is sealed.
Flashing Fast
(0.25 sec on/
0.25 sec off)
Zone is in alarm condition.
Flashing Slow
(1 sec on/
1 sec off)
Zone is manually isolated or
selected to be isolated.
3.2 AWAY Indicator
The AWAY indicator displays that the
system is armed in AWAY Mode. The
AWAY indicator flashes in unison with
the STAY indicator when
programming various options
throughout the Operators Manual.
Refer to Section 3.10.2 Arming in AWAY
Mode for information on the different
methods of arming the system in
AWAY Mode.
Table 3: AWAY Indicator
Indicator Definition
On System is armed in AWAY Mode.
Off System is not armed in AWAY Mode.
3.3 STAY Indicator
The STAY indicator displays that the
system is armed in STAY Mode 1 or
STAY Mode 2. The STAY indicator also
flashes in unison with the AWAY
indicator when programming various
options throughout the Operators Manual.
Refer to Section 3.10.3 Arming in STAY
Mode 1 for different methods of arming in
STAY Mode 1. Refer to Section 3.10.4
Arming in STAY Mode 2 for the method of
arming in STAY Mode 2.
Table 4: STAY Indicator
Indicator Definition
On System is armed in STAY Mode 1
or STAY Mode 2.
Off System is not armed in STAY
Mode 1 or STAY Mode 2.
Flashing
twice a sec
Zone isolating mode or setting
STAY Mode 2 zones.
Flashing once
every
3 sec
Day alarm status – day alarm
turned on.
3.4 System Disarmed
This indicator displays with the
indicator when the system is disarmed.
3.5 MAINS Indicator
The MAINS indicator displays that the
system’s AC MAINS supply is normal or
failed.