ICP-CC488 | User's Guide | 14. Testing EN | 15
Bosch Security Systems, Inc. | 12/08 | F01U089456-02
To disable the Telco Disarm Sequence,
enter the Call Forward Sequence as [*4]
(break) for Step 3.
Table 12: Telco Arm/Disarm Dialing Digits
Digit
Required
Number to
Program
Digit
Required
Number to
Program
0 0 8 8
1 1 9 9
2 2
3 3 * *1
4 4 # *2
5 5 4-sec
Pause
*3
6 6 Break *4
7 7
14. Testing
The following functions let you confirm that your
system is operating correctly:
14.1 Horn Speaker Test
Hold the [1] key until two beeps sound.
The horn speaker sounds for 2 sec.
14.2 Bell Test
Hold the [2] key until two beeps sound.
The bell output operates for 2 sec.
14.3 Strobe Test
1. Hold the [3] key until three beeps sound.
The strobe flashes.
2. Hold the [3] key until two beeps sound.
The strobe stops flashing.
14.4 Walk Test Mode
Use Walk Test Mode to test detection devices to
ensure that they are operating correctly. Every time
you test a zone, the codepad sounds one long beep,
and the horn speaker sounds one short beep to
indicate that the zone is activated when testing.
1. Enter your four character Master Code, followed
by the [7] and [#] keys (for example, [25807#]).
Three beeps sound, and the STAY and AWAY
indicators flash. The codepad beeps once every
sec while the system is in Walk Test Mode.
2. Activate all zones requiring the test.
3. When you finish testing all required zones, press
the [#] key to exit from this mode. Two beeps
sound, and the STAY and AWAY indicators
turn off. The system returns to the disarmed
state.
14.5 Test Report
This feature only applies if your system reports using
the telephone. By holding down the [9] key until two
beeps sound, the system sends a Test Report.
15. Event Memory
Use this function to replay the last 40 events that the
system recorded. The event memory history replays
all alarms and the arming/disarming of the system in
AWAY Mode, STAY Mode 1, and STAY Mode 2.
However, the system cannot differentiate between
arming the system in STAY Mode 1 or STAY Mode
2.
How to Enter Event Memory
Enter your four-character Master Code, followed by
[8] and the [#] button (for example, [25808#]).
Three beeps sound. The last 40 events display one at
a time by the codepad indicators, starting with the
most recent event. A beep sounds as each event
displays.
16. Day Alarm
Day alarm monitors a combination of zones during
the disarmed state. It beeps the codepad buzzer if
activated. Only your installer can program zones 1 to
4 to operate for day alarm.
Example
A day alarm can be configured for the front door of
a shop with a pressure mat or electronic beam that
customers activate as they enter the shop. When
customers step on the pressure mat or break the
electronic beam, the codepad buzzer beeps.
How to Turn Day Alarm On
Hold down the [4] key until three beeps sound.
Day alarm turns on. All zones programmed for day
alarm operation cause the codepad buzzer to beep
during the disarmed state when activated.
How to Turn Day Alarm Off
Hold down the [4] key until two beeps sound.
Day alarm turns off.
17. Codepad Buzzer Tone
Change
Hold down the [8] key to change the tone of the
codepad buzzer. There are 50 different tones, from
1500 Hz to 5000 Hz. If multiple codepads are
installed, each codepad can have a different tone.