To activate this mode, you must enable IVA by selecting either IVA [number] or IVA [number]
Flow in the field Analysis type of the page VCA (from the page Configuration, select Alarm >
VCA). Refer to the current Operation Manual for IVA Intelligent Video Analysis for specific
information.
If the option Show VCA metadata is selected in 'Live' functions (from the page Configuration,
select Web Interface > 'Live' functions), the live view will show the following metadata
objects in the Live page view:
Objects in motion are initially identified in the video.
Actively tracked object in motion are identified in the video.
When an object in motion is lost, a diamond appears designating the area where the
target was lost.
Several reasons may cause the Intelligent Tracking to stop tracking a target:
The target has stopped moving while being followed by Intelligent Tracking.
The target has moved behind a static object in the scene.
In these instances, Intelligent Tracking switches to the IDLE mode (pink eye icon) and waits
for the target to reappear in the scene. The camera will restart tracking if a target starts
moving in the same area where the initial target stopped moving or if the camera detects an