Installation 41/64
RE 92511-01-B/2019-10-09, A15V(L)O Series 11, Bosch Rexroth AG
Y
T
1
M
A
X
A
M T
2
S
P
T
3
Power connection
maximum 750 mA
Fig. 17: Port overview D2 controller, clockwise rotation
Table 12: Ports A15VO/A15VLO series 11
Ports
1)
p
max
[bar]
2)
State
3)
A Working port 420 O
S Suction port(without charge pump) 30 O
S Suction port(with charge pump) 2 O
T
1
Drain port 10 O
4)
T
2
Drain port 10 X
4)
T
3
Drain port 10 X
4)
CR Pilot signal (CR only) 420 O
PR Pilot signal (PR only) 420 O
H3, H4 Pilot signal (only on H3, H4) 100 O
X Pilot signal (S0 and DG only) 420 O
X Measuring port(only on D2) 50 X
Y Pilot signal (only on D2) 50 O
M Control pressure measuring 420 X
M
A
Measuring pressure A 420 X
P External control pressure
(Type code digit 8 version B or C = with external
c
ont
rol pressure supply)
50 O
Port P is without function
(Type code digit 8 version A = without external
control pressure supply)
420 X
1)
The measuring system and thread sizecan be found in the installation drawing.
2)
Depending on the application, momentary pressure peaks can occur. Keep this in mind when
selecting measuring devices and fittings.
3)
O = Must be connected (comes plugged)
X=Plugged (in normal operation)
4)
Depending on the installation position, T
1
, T
2
or T
3
must be connected (seechapter 7.3
"Installation position" on page 29).
WARNING! Port X pressurization with D2 controller!
Port X of D2 controllers is a measuring portonly. External pressurization leads to an
impermissible pressure increase and can cause serious injury or death, or can cause
damage to the axial piston unit.
▶ Make sure that no external pressure is applied at portX.