42/64 Installation
Bosch Rexroth AG, A15V(L)O Series 11, RE 92511-01-B/2019-10-09
The following tightening torques apply:
Fittings:
Observe the manufacturer's specifications regarding the tightening torques of the
fittings used.
Female threads in the axial piston unit:
The max. permissible tightening torques M
G max
are the maximum values for the
female threads and should not be exceeded. For values, seeTable 13.
Threaded plugs:
For the metallic threaded plugs supplied with the axial piston unit, the required
tightening torques of threaded plugs M
V
apply. For values, seeTable 13.
Mounting bolts:
For mounting bolts with metric ISO threads according to DIN13 and/or ASME
B1.1 threads, we recommend checking the tightening torque in individual cases in
accordance with VDI 2230.
In addition to the ports specified in Table 12 "Ports A15VO/A15VLO series 11" on
page 41, axial piston units may have openings that are also closed with a
threaded plug. These plugs must not be opened on the customer side! If you have
opened the threaded plug accidentally, please contact your local contact person
to ensure safe re-closing of the plug. You can find the address at
www.boschrexroth.com/addresses