Technical Data of the Connection Point
View Identifica‐
tion
Function
L+ Connection points for connecting DC bus connections
L-
Screw connection
M6 thread at device (terminal block)
Unit Min. Max.
Tightening torque Nm 5,5 6,5
Short circuit protection Via fusing elements connected in the incoming circuit to the
mains connection
Overload protection Via fusing elements connected in the incoming circuit to the
mains connection
Current carrying capacity "looping through" from L+ to L+, L- to L-
(contact bars in scope of supply of accessory HAS01)
With contact bars -072 A 220
Additionally with contact bars ‑042 and end
piece
A 245
Fig.5-12: Function, Pin Assignment, Properties
DOK-INDRV*-KCU02*UL***-IN01-EN-P
Rexroth IndraDrive Mi Electronic Control System KCU02
Bosch Rexroth AG 39/69
Instructions for Use