4.5.7 Display I/O signals
All input and output signals of the timer can be visualized on the BT 6.
L Proceed as follows to display the signals:
1. Press
key.
2. Move the cursor to the ”DIAGNOSTIC” line with the keys
or .
3. Press
key.
The BT 6 will open a screen in which a maximum of 8 signals can be
displayed.
Line 1 specifies whether the signals displayed refer to inputs or out-
puts of the timer.
The following texts may be displayed in the beginning of line 2:
D ”ser.”:
the signals displayed are of the ”serial” type (transmission via se-
rial bus). This signal type is additionally separated from the 2-digit
signal numbers by the ”S” character (e.g. S00, S01, etc.).
D ”ext.”:
the signals displayed are of the ”external” type (transmission via
hardware I/O). This signal type is additionally characterized by an
”E” (input) or an ”A” (output) in front of the 2-digit signal numbers
(e.g. E00, A00, etc.).
D ”int.”:
the signals displayed are of the ”internal” type (signal is generated
internally by the timer). This signal type is additionally character-
ized by the ”I” (internal) character in front of the 2-digit signal num-
bers.
The respective signal status (active / not active) is always signaled by
the signal number and, separated by the character ”:”, by ”0” (not ac-
tive) or ”1” (active).
4. To display additional maximally 8 signals, press
.
The BT 6 will open the next screen.
In order to return to the previous screen, press
.
L In order to get back to the main menu: Press
key.