RE95230-B/2021-12-01, BoschRexrothAG
Installation | Analog amplifier RA 25/48
max. 12cm
Fig� 13: Lead the wires away in alight bend
Ensure correct stripping length (4mm) and correct crimping
(see TE Connectivity documents 114-18022 and 114-18050).
Wire protruding max. 1mm
Insulation crimped
Insulation not crimped
Correct crimping
Incorrect crimping
Hook
Fig� 14: Correct stripping length
The catch of the contact must be engaged in the detent locking of the contact
carrier.
Verify this by pulling on the line (tensile test).
Immediately consider internal bridges and - if necessary - wiring elements
(resistance) in the connector and install them according to the following
instructions.