7 Commissioning
1. Connect the PE wire.
2. Open the SB356 if it is locked.
3. Remove both covers (A) and (B) by
loosening the six screws:
Fig. 9: Removing the cover
4. Select the voltage (factory setting:
400 V).
5. Set the Q0 power switch to the
appropriate position (see Table 3).
CAUTION
Risk of damage to persons
and property!
Commissioning of the SB356
system box requires basic
mechanical and electrical
knowledge.
y Only qualified personnel (see
“Personnel qualifications” on
page 24) are authorized to
commission the system.
CAUTION
Danger to life due to
insufficient emergency OFF
equipment!
Emergency OFF equipment must
be functioning and within reach in
all system modes. Release of the
emergency OFF equipment may
not result in an uncontrolled
system restart!
y Always check the emergency
OFF chain before switching on
the system!
y Further information on the
emergency OFF can be found
in the instruction manual for
the VM350 power supply
module (3 609 929 B32).
CAUTION
Overheating of the SB356 sys-
tem box and its components!
Damage to the system box and its
components from overheating
y Always keep the air ways for
cooling the SB356 system box
clear.
A
B