Indicator / adjustment elements (continued)
Assignment of DIL switch settings on the card to the valve
types (see also label on the printed-circuit board)
Meaning of potentiometers "Zw" (R130) and "Gw":
– Adjustment of biasing current by means of potentiometer
"Zw" (R130)
• Turning clockwise → increase in biasing current
• Turning counter-clockwise → reduction of biasing current
– Adjustment of the max. command value by means of potenti-
ometer "Gw"
• Turning clockwise → increase in command value
• Turning counter-clockwise → reduction of command value
1)
Up to component series 5X
ON
1
2
3456
7
ON
1
2
3456
7
ON
1
2
3456
7
ON
1
2
3456
7
1
2
3456
7
ON
X
1
2
3456
7
ON
X
1
2
3456
7
ON
X
0 … 20 mA
ON
1
2
3456
7
4 … 20 mA
ON
1
2
3456
7
Setting for valve
types:
S15 ... S17
(BR15 ... BR17)
S21 ... S27
(BR21 ... BR27)
Setting valid for all
valve types:
S11 ... S14
(BR11 ... BR14)
DBE(M)T, DBE(M)30,
DRE(M)30,
3DRE(M)10
1)
,
3DRE(M)16
1)
,
DBEP6A, DBEP6B,
3DREP6A, 3DREP6B,
pumps
DRE(M)10-5X,
DRE(M)20-5X
DBE(M)10-5X,
DBE(M)20-5X,
3DRE(M)10P-6X,
3DRE(M)16P-6X,
ZDRE10, (Z)DBE6
DRE6,
ZDRE6
Ramp time
Command
value 2
Note (X):
With type VT-VSPA1-1 (component series 10) switch BR22
must be set to “ON” and potentiometer “R130” turned to “left-
hand limit stop” before the correct characteristic curve can be
set.
With type VT-VSPA1-1 (from component series 11) and type
VT-VSPA1K-1, switch
S22 is ineffective. Po ten tio me ter "Zw"
needs not to be operated.
5 s
1 s
ON
1
2
3456
7
ON
1
2
3456
7
+10 V
ON
1
2
3456
7