18 | Vertical configurability SM Series Heat Pump
SM Series Heat Pump6 720 220 406 (2013/1) Subject to change without prior notice
9. Remove and retain (2) horizontal blower
support brackets by removing (4) screws in
each. (Figure #56)
Figure # 56
10. Reinstall brackets removed in Step (9) on the
same side of the unit as the blower outlet.
(Figure #57)
Figure # 57
11. Remove and retain vertical brackets from
blower by removing (4) screws, (2) on each
side of the blower. (Figure #58)
Figure # 58
12. Reinstall vertical brackets in new orientation.
(Figure #59)
Figure # 59
13. Reinstall the blower assembly in the new
desired location, using the existing holes.
(Figure #60)
Figure # 60
Upper bracket contains two push-in rubber
bump stops.
Ensure bracket with push-in rubber bump stops
is installed in the top position.
Be aware of blower housing proximity to air
side coil and potential for coil damage.