Installation, Operation, and Maintenance Manual
SM Split CS Series Heat Pump
8733825873 (2020/05)
SM024 | SM036 | SM048 | SM060

Questions and Answers

  • M
    mchristianAug 9, 2025
    Why is my Bosch Split CS SM048 not cooling or heating enough?
    • B
      Beth JohnsonAug 9, 2025
      Insufficient cooling or heating in your Bosch Heat Pump can stem from several causes. The unit might be undersized, requiring recalculation of heating/cooling loads, possibly with added insulation. Leaks in ductwork or ambient air entering through doors/windows could cause loss of conditioned air. Inadequate airflow, often due to a dirty filter, can also be a factor. A low refrigerant charge leads to inefficient operation. Other potential issues include a defective compressor or reversing valve, restrictions or defects in the TXV, or contamination of the refrigerant system with moisture or non-condensables. Compare the unit's operating pressures to the pressure/temperature chart to diagnose the issue.
  • K
    Karen MitchellAug 15, 2025
    What to do if my Bosch Split CS SM048 Heat Pump is not running at all?
    • A
      Alexandria ReyesAug 15, 2025
      If your Bosch Heat Pump isn't running, start by checking the power supply. Ensure the disconnect is closed and power is applied. Inspect for blown fuses or tripped breakers, replacing or resetting them as necessary, ensuring correct fuse size. Verify the voltage supply meets the unit's data plate specifications; if it's low, contact your local power company. Also, examine the thermostat. Set the fan to 'ON' to see if the fan runs. Test 'COOL' and 'HEAT' modes with extreme temperature settings to check for proper operation. If issues persist, confirm 24 volts at the low-voltage terminal strip between 'R' and 'C,' 'Y' and 'C,' and 'O' and 'C,' and between 'G' and 'C' in the air handler. Replace the thermostat if it's defective.
  • S
    Scott ParksAug 20, 2025
    Why does my Bosch Split CS SM048 Heat Pump turn off due to high pressure?
    • R
      rogersrobertAug 20, 2025
      Your Bosch Heat Pump might be shutting down due to high pressure for a few reasons. In 'COOLING' mode, check for insufficient water flow, excessively warm entering water temperature, or a scaled/plugged condenser. In 'HEATING' mode, ensure adequate fluid flow on the load side, and verify the blower is operational, the filter isn't clogged, and ductwork isn't restricted. An overcharged refrigerant level can also cause this issue; in that case, reclaim refrigerant, evacuate, and recharge to the factory-recommended level. Finally, inspect the high-pressure switch for defects or improper calibration.
  • M
    mclayAug 27, 2025
    What causes a Bosch Split CS SM048 to shut off due to low pressure?
    • B
      bryancurryAug 27, 2025
      A Bosch Heat Pump shutting off due to low pressure can be attributed to several factors. In 'COOLING' mode, investigate potential issues such as insufficient airflow, excessively cold entering air temperature, a non-operational blower, a clogged filter, or ductwork restrictions. If in 'HEATING' mode, check for inadequate water flow, excessively cold entering water temperature, or a scaled/plugged condenser. A low refrigerant charge is another possibility; look for refrigerant leaks, repair them, evacuate the system, and recharge with the factory-recommended amount. Lastly, examine the low-pressure switch for any defects or calibration problems.
  • V
    Vanessa StoutSep 2, 2025
    How to fix a Bosch Heat Pump that short cycles?
    • B
      Barbara FarleySep 2, 2025
      If your Bosch Heat Pump is short cycling, several factors could be responsible. The unit might be oversized, requiring recalculation of heating or cooling loads. The thermostat's location could be the problem if it's near a supply air grill; try relocating it and adjusting the heat anticipator. Also, check the wiring and controls, specifically looking for a defective or improperly calibrated low-pressure switch.

Summary

Document Conventions and Safety

General Safety Warnings and Precautions

Important safety notes for installation, electrical, and refrigerant handling.

UNIT INSTALLATION

Installation Procedures

REFRIGERANT LINES

Refrigerant Line Sizing and Charge

Refrigerant Charge Adjustments

Refrigerant Line TXV Adjustments

Electrical

Wiring and Connection Safety

Important safety notes for electrical wiring.

Safety Devices and the UPM Controller

UPM Controller Overview and Safety Controls

Explanation of the Unit Protection Module and its safety features.

UPM Controller Settings and Features

Default Settings and DIP Switch Options

Factory default settings and selectable positions via DIP switches.

Key UPM Controller Features

Describes timers and bypass features of the UPM.

UPM Controller Protection Features

Power Interruption and Malfunction Outputs

Protection against power issues and malfunction signaling.

Test Mode and Freeze Sensor Operation

Using test mode and freeze sensor settings.

TYPICAL SYSTEM SETUP

POST-INSTALLATION SYSTEM CHECKOUT

System Pre-Energization Checks and Guidelines

Essential checks before powering the unit and important installation notes.

SYSTEM OPERATION

Unit Start-Up and Sequence of Operation

Step-by-step startup and general operation overview.

Sequence of Operation Details

Cooling Mode Operation Details

Detailed operation in cooling mode, including fan and compressor staging.

Heating Mode Operation Details

Detailed operation in heating mode, including auxiliary heat.

SmartStart Assist Technical Details

SmartStart Assist Operational Notes

CHECK-OUT SHEET

Operating Conditions Recording

Sections to record operating parameters for cooling and heating.

TROUBLESHOOTING

Unit Troubleshooting: Unit Does Not Run

Diagnosing and correcting issues when the unit is completely off.

Unit Troubleshooting: High-Pressure Control Issues

Diagnosing and correcting high-pressure control problems.

Unit Troubleshooting: Low-Pressure Control Issues

Diagnosing and correcting low-pressure control problems.

Troubleshooting Performance Issues

Unit Troubleshooting: Short Cycling

Diagnosing and correcting short cycling problems.

Unit Troubleshooting: Insufficient Cooling;Heating

Diagnosing and correcting performance deficiencies.

SmartStart Assist Troubleshooting

SmartStart Assist LED and Relay Troubleshooting

Table for troubleshooting SmartStart Assist based on LED and relay status.

UPM LED Status Indicator (Blink Code) Information

UPM LED Status Indications

Table detailing UPM LED blink codes and their meanings.

Compressor Ohms

OPERATING TEMPERATURES AND PRESSURES

Operating Temperatures and Pressures Data

MAINTENANCE

WIRING DIAGRAMS

Unit Wiring Diagram

Diagram illustrating the unit's electrical wiring schematic.

DIMENSIONAL DRAWINGS