EasyManua.ls Logo

Bosch SM070 - Page 22

Bosch SM070
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22 | Vertical configurability SM Series Heat Pump
SM Series Heat Pump6 720 220 406 (2013/1) Subject to change without prior notice
4. Remove and retain Electric Heat
Element(s).(Figure#74)
Figure # 74
5. Disconnect main Electric Heat E-box
plug.(FIgure#75)
Figure # 75
6. Remove and retain Electric Heat E-box by
removing (2) screws.(Figure#76)
Figure # 76
7. Re-install Electric Heat E-box in the new
location. (Figure#77)
Figure # 77
8. Remove and retain Blower collar cover(s).
(FIgure#78)
Figure # 78
9. Re-install Electric Heat Elements in the new
location. Ensure High Temperature Cutouts are
located on the left side. (Figure#79)
Figure # 79

Table of Contents

Other manuals for Bosch SM070

Related product manuals