Page #37 background imageLoading...
Page #37 background image
37
Bosch Security Systems 09/07 BLCC500R FTR1.02


Copyright © 2007 E&OE
Comms > Dialler Reporting >
Burg Report Delay
MENU 5-4-6
0 0 0
SECONDS
Enter 0 – 255 seconds + [OK] To Program The Delay Time In Seconds
Before Reports Are Sent. 0 = No Delay (*** System Wide Parameter ***)
Comms > Dialler Reporting >
Fire Report Delay
MENU 5-4-7
0 0 0
SECONDS
Enter 0 – 255 seconds + [OK] To Program The Delay Time In Seconds
Before Reports Are Sent. 0 = No Delay (*** System Wide Parameter ***)
Comms > Comms Test >
Send Test Report
MENU 5-9-0
Comms > Comms Test >
Test Report Time
MENU 5-9-1
Test Time
02 : 00
HH MM
Use the [] and [] keys to move to the field then [] and [] to
change. Press [OK] to save or [MENU] to exit without saving.
i


Comms > Comms Test >
Test Report Period
MENU 5-9-2
0 = No Test Report
1
1 = Every Day
2 = Every Week
3 = Every Month
MENU 5-9-2 Programs The Interval Between Automatic Test Reports.
Enter [0] to [3] + [OK] To Program the required value.
(*** System Wide Parameter ***)
Comms > Comms Test >
Test Report Options
MENU 5-9-3
1 Send Test Reports Only If No Other Report N
2 Send Test Reports On Siren Reset / Time Out Y
3 Reserved N
4 Reserved N
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Comms > Comms Test >
Test Route
MENU 5-9-4
0 = Report Events To Log Only
1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
Enter 0 - 4 + [OK]. To Enter Single Option Only.
(*** System Wide Parameter ***)
Comms > Comms Test >
Dial Number Test
MENU 5-9-5
Use the option to test the system dialer to your mobile or other phone.
Enter the digits to dial and press OK. The system will call the number
entered. This function will stop after 30 seconds or by pressing OK.
Enter [0] – [9] For Telephone Digits.
Use [] and [] To Toggle Special Characters # and , (Pause)
Devices > Commands >
LAN Status
MENU 6-0-0
LAN Secure
MENU 6-0-1
Devices > Keypads >
Keypad Volume
MENU 6-1-0
Keypad Contrast
MENU 6-1-1
Keypad Backlight
MENU 6-1-2
Devices > Keypads >
Home Area
MENU 6-1-3
1
Enter 1 - 4 Then Press [OK] To Set The Home Area. This is the Area
which will be diplayed on the keypad by default.
i

All keypads must have a home area programmed
to work correctly.
Devices > Keypads >
General Options
MENU 6-1-4
1 Keypad Extinguish N
2 Greeting On Arming Y
3 Greeting On Disarming Y
4 Enable Rear Tamper N
5 PIN To Change Area N
6 Home Area Only N
7 Report/Display Keypad Temperature N
8 Display Area ICON Indicators N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.

Other manuals for Bosch Solution 16i