38
Bosch Security Systems 09/07 BLCC500R FTR1.02

Copyright © 2007 E&OE
Devices > Keypads >
Beeper Options
MENU 6-1-5
1 Trouble Alert Beeps Y
2 Entry Warning Y
3 Exit Warning Y
4 Chime Tone Y
5 Display Temperature N
6 PIN Arming Not Allowed N
7 Intaller PIN Not Allowed N
8 Show Alarm When Armed N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Devices > Keypads >
Emergency Keys
MENU 6-1-6
1 Audible Keypad Fire Y
2 Report Keypad Fire Y
3 Audible Keypad Medical Y
4 Report Keypad Medical Y
5 Audible Keypad Panic (Invisible If Not Set) Y
6 Report Keypad Panic Y
7 Reserved N
8 Reserved N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Devices > Keypads >
Access Group
MENU 6-1-7
0
Enter 1 - 8 + [OK] To Assign The Keypad To An Access Group.
Devices > Keypads >
Lockout Time
MENU 6-1-8
0 6 0
SECONDS
Enter 0 – 255 + [OK] To Program The Keypad Lockout Time In
Seconds. 0 = No Lockout (*** System Wide Parameter ***)
Devices > RF Devices >
Receiver Options MENU 6-2-0
1 Display RF Receiver Trouble Y
2 Alarm On RF Receiver Tamper Y
3 Report RF Receiver Tamper Y
4 Alarm On RF Receiver Jam Detect N
5 Report RF Receiver Jam Detect N
6 Alarm On RF Receiver Comms Fail Y
7 Report RF Receiver Comms Fail Y
8 Reserved N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Device > RF Devices >
Supervision Time
MENU 6-2-1
0 2 4
HOURS
Enter the RF Supervision Time for Devices in Hours (001 - 255 Hours)
000 = No Supervision
Device > RF Devices >
RF Device Options MENU 6-2-2
1 Display RF Tamper Y
2 Report RF Tamper Y
3 Report RF Low Battery Y
4 Report Lost RF Device Y
5 Open Zone On Lost RF N
6 Audible Keyfob Panic Y
7 Report Keyfob Panic Y
8 Keyfob Function 1 Key = Part On Y
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Devices > RF Devices >
Add RF Keypad
MENU 6-2-3
Delete RF Keypad
MENU 6-2-4
View RF Device ID
MENU 6-2-5
Devices > Serial Device >
Device Type
MENU 6-3-0
0 = Disabled
0
1 = Serial Printer
2 = Computer
Enter 0 – 8 + [OK] To Program The Type Of Serial Device Connected To
The Serial Port.
Devices > Serial Device >
Baud Rate
MENU 6-3-1
0 = No Device Connected
0
1 = 300 Baud 5 = 9600 Baud
2 = 600 Baud 6 = 19200 Baud
3 = 1200 Baud
4 = 2400 Baud
Enter Digits 0 – 6 To Program The Serial Device Baud Rate, Then Press
[OK] To Save.
Devices > Serial Device >
Flow Control
MENU 6-3-2
0 = No Handshaking
0
1 = Hardware
2 = Xon-Xoff
Enter Digits 0 – 2 To Program The Serial Device Flow Control, Then
Press [OK] To Save.

Other manuals for Bosch Solution 16i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 16i and is the answer not in the manual?

Bosch Solution 16i Specifications

General IconGeneral
BrandBosch
ModelSolution 16i
CategorySecurity System
LanguageEnglish

Related product manuals