EasyManua.ls Logo

Bosch Solution 880 CC408 - Dialler Options and Line Fail Handling; Programming Parameters: Alarm Link & User Management; Alarm Link Options and Installer Code; User Code Programming and Authority Levels

Bosch Solution 880 CC408
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CC408 | Quick Reference Guide | 3. Programming Parameters EN | 10
Bosch Security Systems | 6/04 | 4998152468B
3.1.13 Telco Arming Sequence (Call
Forward On)
Location
113 to 142
Default
0
3.1.14 Telco Disarm Sequence (Call
Forward Off)
Location
143 to 158
Default
0
3.1.15 Call Back Telephone Number
Location
159 to 174
Default
0
0 = 10 and telephone termination = 0
Anywhere else 0 = 0
3.1.16 Ring Count
Location
175
Default
8
0 Panel does not answer
1 to 13 Number of rings until panel answers
14 Answering machine bypass 2
15 Answering machine bypass 1
3.1.17 Telephone Line Fail Options
Location
176
Default
0
1 Display FAULT indicator when telephone line fails
2 Sound alarm when system arms
4 Sound alarm when system disarms
Options 2 and 4 must be used in
conjunction with Option 1 (for
example, program 1, 3, 5, or 7).
3.1.18 Dialler Options 1
Location
177
1 Dialler reporting functions allowed
2 Remote arming by telephone allowed
4 Answering machine bypass only when armed
8 Bell 103 used for FSK format (Disabled = CCITT
V21)
3.1.19 Dialler Options 2
Location
178
Default
0
1 Open/Close Reports only if previous alarm
2 Open/Close Reports for STAY Mode 1 and STAY
Mode 2
4 Delay siren until transmission complete
8 Extend handshake wait time from 30 seconds to
55 seconds
3.1.20 Dialler Options 3
Location
179
Default
0
1 Set DTMP dialling pulses to 1 digit/second
2 Reserved
4 Change decadic dialling to 60/40
8 Reserved
3.2 Alarm Link Options
Location
180
1 Upload/download allowed
2 Call back phone number required for
upload/download
4 Exit upload/download connection on alarm
8 External modem module (CC811) required
3.3 Installer Code
Location
181 to 184
Location Default
181 1
182 2
183 3
184 4
3.4 User Code Programming
3.4.1 User Codes
Location
185 to 264
Location Default*
User #01
185 2
186 5
187 8
188 0
Authority Level* 189 10
User #02
190 to 193 15
Authority Level* 194 2
User #03
195 to 198 15
Authority Level* 199 2
User #04
200 to 203 15
Authority Level* 204 2
User #05
205 to 208 15
Authority Level* 209 2
User #06
210 to 213 15
Authority Level* 214 2
User #07
215 to 218 15
Authority Level* 219 2
User #08
220 0
221 to 223 15
Authority Level* 224 3
RF User #09
225 to 228 15
Authority Level* 229 2
RF User #10
230 to 233 15
Authority Level* 234 2
RF User #11
235 to 238 15
Authority Level* 239 2
RF User #12 240 to 243 15
Authority Level* 244 2
RF User #13 245 to 248 15
Authority Level* 249 2
RF User #14 250 to 253 15
Authority Level* 254 2

Table of Contents