CC408 | Quick Reference Guide | 3. Programming Parameters EN | 10
Bosch Security Systems | 6/04 | 4998152468B
3.1.13 Telco Arming Sequence (Call
Forward On)
Location
113 to 142
Default
0
3.1.14 Telco Disarm Sequence (Call
Forward Off)
Location
143 to 158
Default
0
3.1.15 Call Back Telephone Number
Location
159 to 174
Default
0
0 = 10 and telephone termination = 0
Anywhere else 0 = 0
3.1.16 Ring Count
Location
175
Default
8
0 Panel does not answer
1 to 13 Number of rings until panel answers
14 Answering machine bypass 2
15 Answering machine bypass 1
3.1.17 Telephone Line Fail Options
Location
176
Default
0
1 Display FAULT indicator when telephone line fails
2 Sound alarm when system arms
4 Sound alarm when system disarms
Options 2 and 4 must be used in
conjunction with Option 1 (for
example, program 1, 3, 5, or 7).
3.1.18 Dialler Options 1
Location
177
1 Dialler reporting functions allowed
2 Remote arming by telephone allowed
4 Answering machine bypass only when armed
8 Bell 103 used for FSK format (Disabled = CCITT
V21)
3.1.19 Dialler Options 2
Location
178
Default
0
1 Open/Close Reports only if previous alarm
2 Open/Close Reports for STAY Mode 1 and STAY
Mode 2
4 Delay siren until transmission complete
8 Extend handshake wait time from 30 seconds to
55 seconds
3.1.20 Dialler Options 3
Location
179
Default
0
1 Set DTMP dialling pulses to 1 digit/second
2 Reserved
4 Change decadic dialling to 60/40
8 Reserved
3.2 Alarm Link Options
Location
180
1 Upload/download allowed
2 Call back phone number required for
upload/download
4 Exit upload/download connection on alarm
8 External modem module (CC811) required
3.3 Installer Code
Location
181 to 184
Location Default
181 1
182 2
183 3
184 4
3.4 User Code Programming
3.4.1 User Codes
Location
185 to 264
Location Default*
User #01
185 2
186 5
187 8
188 0
Authority Level* 189 10
User #02
190 to 193 15
Authority Level* 194 2
User #03
195 to 198 15
Authority Level* 199 2
User #04
200 to 203 15
Authority Level* 204 2
User #05
205 to 208 15
Authority Level* 209 2
User #06
210 to 213 15
Authority Level* 214 2
User #07
215 to 218 15
Authority Level* 219 2
User #08
220 0
221 to 223 15
Authority Level* 224 3
RF User #09
225 to 228 15
Authority Level* 229 2
RF User #10
230 to 233 15
Authority Level* 234 2
RF User #11
235 to 238 15
Authority Level* 239 2
RF User #12 240 to 243 15
Authority Level* 244 2
RF User #13 245 to 248 15
Authority Level* 249 2
RF User #14 250 to 253 15
Authority Level* 254 2