EasyManua.ls Logo

Bosch Solution 880 CC408 - Programming Parameters: Zone Configuration Basics; Zone Default Programming

Bosch Solution 880 CC408
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CC408 | Quick Reference Guide | 3. Programming Parameters EN | 11
Bosch Security Systems | 6/04 | 4998152468B
3.4.1 continued
Location
185 to 264
Location Default*
RF User #15 255 to 258 15
Authority Level* 259 2
RF User #16 260 to 263 15
Authority Level* 264 2
* Refer to Section 3.4.2 User Code Authority Levels for
Authority Level descriptions.
3.4.2 User Code Authority Levels
Authority
Level
Description
0 Arm/disarm
1 Arm only
2 Arm/disarm and open/close reports
3 Arm only and close reports
4 Arm/disarm and code required to isolate
6 Arm/disarm and open/close reports and
code required to isolate
8 Master code and arm/disarm
10 Master code and arm/disarm and
open/close reports
12 Master code and arm/disarm and code
required to isolate
14 Master code and arm/disarm and code
required to isolate and open/close reports
3.5 Day Alarm Zones
Location
265
Default
0
1 Zone 1
2 Zone 2
4 Zone 3
8 Zone 4
3.6 EOL Resistor Value
Location
266
0 No EOL
1 1K
2 1K5
3 2K2
4 3K3
5 3K9
6 4K7
7 5K6
8 6K8
9 10K
10 12K
11 22K
12 Reserved
13 Reserved
14 Reserved
15 Split EOL (3K3/6K8)
Eight burglary zones
3.7 Zone Default Programming
3.7.1 Zone Defaults
Location
267 to 322
Location Default
Zone #01 (Default = Delay 1)
Zone Type 267 2
Zone Pulse Count 268 0
Zone Pulse Count Time 269 0
Zone Option 1 270 1
Zone Option 2 271 14
Report Code 272 1
Dialler Options 273 1
Zone #02 (Default = Handover)
Zone Type 274 1
Zone Pulse Count 275 0
Zone Pulse Count Time 276 0
Zone Option 1 277 1
Zone Option 2 278 14
Report Code 279 1
Dialler Options 280 1
Zone #03 (Default = Handover)
Zone Type 281 1
Zone Pulse Count 282 0
Zone Pulse Count Time 283 0
Zone Option 1 284 1
Zone Option 2 285 14
Report Code 286 1
Dialler Options 287 1
Zone #04 (Default = Handover)
Zone Type 288 1
Zone Pulse Count 289 0
Zone Pulse Count Time 290 0
Zone Option 1 291 1
Zone Option 2 292 14
Report Code 293 1
Dialler Options 294 1
Zone #05 (Default = Instant)
Zone Type 295 0
Zone Pulse Count 296 0
Zone Pulse Count Time 297 0
Zone Option 1 298 1
Zone Option 2 299 14
Report Code 300 1
Dialler Options 301 1
Zone #06 (Default = Instant)
Zone Type 302 0
Zone Pulse Count 303 0
Zone Pulse Count Time 304 0
Zone Option 1 305 1
Zone Option 2 306 14
Report Code 307 1
Dialler Options 308 1

Table of Contents