CC408 | Quick Reference Guide | 3. Programming Parameters EN | 12
Bosch Security Systems | 6/04 | 4998152468B
3.7.1 continued
Location
267 to 322
Location Default
Zone #07 (Default = Instant)
Zone Type 309 0
Zone Pulse Count 310 0
Zone Pulse Count Time 311 0
Zone Option 1 312 1
Zone Option 2 313 14
Report Code 314 1
Dialler Options 315 1
Zone #08 (Default = 24-hour Tamper)
Zone Type 316 9
Zone Pulse Count 317 0
Zone Pulse Count Time 318 0
Zone Option 1 319 1
Zone Option 2 320 12
Report Code 321 1
Dialler Options 322 1
3.7.2 Zone Types
Zone Type Description
0 Instant
1 Handover
2 Delay 1
3 Delay 2
4 Reserved
5 Reserved
6 24-hour medical
7 24-hour panic
8 24-hour hold-up
9 24-hour tamper
10 Reserved
11 Keyswitch
12 24-hour burglary
13 24-hour fire
14 Chime
15 Not used
3.7.3 Zone Pulse Count
Use the pulse count to program the number of
pulses (0 to 15) that must register within the pulse
count time to activate an alarm.
3.7.4 Zone Pulse Count Time
Option 20 ms Loop
Response
Time
Option 150 ms Loop
Response
Time
0 0.5 seconds 8 20 seconds
1 1 second 9 30 seconds
2 2 seconds 10 40 seconds
3 3 seconds 11 50 seconds
4 4 seconds 12 60 seconds
5 5 seconds 13 90 seconds
6 10 seconds 14 120 seconds
7 15 seconds 15 200 seconds
3.7.5 Zone Options 1
Option Description
1 Lockout siren/dialler
2 Delay Alarm Report
4 Silent alarm
8 Sensor watch
3.7.6 Zone Options 2
Option Group
1 Isolated in STAY Mode 1
2 Zone isolation allowed
4 Forced arming allowed
8 Zone Restore Report allowed
3.7.7 Zone Dialler Options
Option Description
0 No Zone Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1
fails
3.7.8 Keyswitch Zone Options
The keyswitch zone options replace Zone Options
1 for zones programmed to operate as keyswitch
zones.
Option Description
0 Latching arm and disarm in AWAY Mode
1 Latching arm in AWAY Mode
2 Latching disarm from AWAY Mode or STAY
Mode
4 Latching arm and disarm in STAY Mode
5 Latching arm in STAY Mode
6 Latching disarm from STAY Mode
8 Momentary arm and disarm in AWAY Mode
9 Momentary arm In AWAY Mode
10 Momentary disarm from AWAY Mode or
STAY Mode
12 Momentary arm and disarm in STAY Mode
13 Momentary arm in STAY Mode
14 Momentary disarm from STAY Mode
3.8 Swinger Shutdown Programming
3.8.1 Swinger Shutdown Count for Siren
Location
323
Default
3
0 Unlimited
1 to 15 Number of times siren operates until
lockout
3.8.2 Swinger Shutdown Count for Dialler
Location
324
Default
6
0 Unlimited
1 to 15 Number of times dialler operates until
lockout