Location 438
System Options 3
Location 439
System Options 4
Location 440
Consumer Options 1
Location 441
Consumer Options 2
Location 442
Consumer Options 3
Location 443
Radio Input Options
Location 444
Partitioning Options 1
Location 445
Partitioning Options 2
Location 446 - 453
Zone Allocations For Area 1
Location 454 - 461
Zone Allocations For Area 2
8
1 = AC Fail After 1 Hour (Disabled = After 2 Minutes)
2 = Ignore AC Fail
4 = Pulse Count Handover Allowed
8 = Handover Delay To Be Sequential
0
1 = Panel To Power Up Disarmed (If Power Reset)
2 = Arm/Disarm Tracking On Power Up
4 = Internal Crystal To Keep Time
8 = Radio Keyswitch Interface, Night Arm Station Or RE005 Installed
0
1 = Test Reports Only When Armed
2 = Test Report After Siren Reset
4 = Auto Arm In STAY Mode 1
8 = STAY Indicator To Display Day Alarm Status
2
1 = Codepad Display Extinguish After 60 Seconds
2 = Single Button Arming Allowed (AWAY/STAY Mode 1 & 2)
4 = Single Button Disarming Allowed (STAY Mode 1 & 2)
8 = Alarm Memory Reset On Disarm
1 = Codepad Fault Beeps Allowed
2 = Use Digit 3 For Codepad Duress Alarm (Instead Of Digit 9)
4 = Alarms Activate Sirens and Strobe Outputs In STAY Mode 1 & 2
8 = Zone Tamper Alarms To Be Silent
5
0
1 = DS 304Mhz RF Receiver (RF3212)
2 = Latching Keyswitch Input
3 = Momentary Keyswitch Input
4 = Reserved
0
1 = First To Open/Last To Close Reporting Allowed
2 = Area 1 Codepad Connected To Data Terminal
4 = Reset Sirens From Any Area Allowed
8 = Master Codepad To Display AUX Indicator When On-Line
0
1 = Lock Area 1 To Receiver 1 & Lock Area 2 To Receiver 2
2 = User Codes Allowed To Arm/Disarm Both Areas At Same Time (Code + 0 + #)
4 = Reserved
8 = Reserved
Location 446 = Zone 1 LED – Area 1 Codepad
Location 447 = Zone 2 LED – Area 1 Codepad
Location 448 = Zone 3 LED – Area 1 Codepad
Location 449 = Zone 4 LED – Area 1 Codepad
Location 450 = Zone 5 LED – Area 1 Codepad
Location 451 = Zone 6 LED – Area 1 Codepad
Location 452 = Zone 7 LED – Area 1 Codepad
Location 453 = Zone 8 LED – Area 1 Codepad
446 447 448 449 450 451 452 453
0 0 0 0 0 0 0 0
Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8
Location 454 = Zone 1 LED – Area 2 Codepad
Location 455 = Zone 2 LED – Area 2 Codepad
Location 456 = Zone 3 LED – Area 2 Codepad
Location 457 = Zone 4 LED – Area 2 Codepad
Location 458 = Zone 5 LED – Area 2 Codepad
Location 459 = Zone 6 LED – Area 2 Codepad
Location 460 = Zone 7 LED – Area 2 Codepad
Location 461 = Zone 8 LED – Area 2 Codepad
454 455 456 457 458 459 460 461
0 0 0 0 0 0 0 0
Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8
Solution Ultima 880
Quick Reference Guide
17
Bosch Security Systems Pty Limited