Data
Value
Zone 1
Indicator
Zone 2
Indicator
Zone 3
Indicator
Zone 4
Indicator
Zone 5
Indicator
Zone 6
Indicator
Zone 7
Indicator
Zone 8
Indicator
MAINS
Indicator
0
1 X
2 X
3 X
4 X
5 X
6 X
7 X
8 X
9 X X
10 X
11 X X
12 X X
13 X X
14 X X
15 X X
Programming Option Bits
You will notice option bits throughout the quick reference guide. This allows you to program any
combination of the four different options in the one location by adding the options together.
Programming a zero (0) will disable all four options.
Example
If at LOCATION 177 you only want options 1, 2 and 4, add the numbers together and the total is
the number to be programmed. In this example, the number to be programmed is 7 (eg. 1 + 2 + 4
= 7).
Option Description
1
Dialler Reporting Functions Allowed
2
Remote Arming Via Telephone Allowed
4 Answering Machine Bypass Only When Armed
8
Use Bell 103 For FSK Format (Disabled = CCITT V21)
Installer’s Programming Commands
These commands can only be used when you enter Installer’s Programming Mode. Enter the
command followed by the # key.
Command Description
958
Enable/Disable Zone Status (Hand Held Programmer Required)
959
Test Programming Key
960 Exit Installer’s Programming Mode
961
Default System Back To Factory Settings
962 Copy Panel Memory To Programming Key
963
Copy Programming Key To Panel Memory
964 Erase Programming Key
965
Default System For Domestic Dialling Format
966
Enable/Disable Automatic Stepping Of Locations When Programming
999
Display Software Version (Hand Held Programmer Required)
4
Solution Ultima 880
Quick Reference Guide
SOL ULTIMA 880 QUICK REF GUIDE.DOCBosch Security Systems Pty Limited