Location 380 - 409
Outputs
Location 380 381 382 383 384 385 Location 386 387 388 389 390 391
Output 1
1 14 0 0 0 0
Output 2
27 10 2 15
Default = Horn
Speaker
Event
Code
Polarity Time
Base
Time Base
Multiplier
Default = Fire Alarm
With Verification
Event
Code
Polarity Time
Base
Time Base
Multiplier
Location 392 393 394 395 396 397 Location 398 399 400 401 402 403
Strobe Output
2 0 6 4 0 8
Relay Output
115 1 0 0 0
Default = Strobe
(Reset After 8 Hrs)
Event
Code
Polarity Time
Base
Time Base
Multiplier
Default = Sirens
Running
Event
Code
Polarity Time
Base
Time Base
Multiplier
Location 404 405 406 407 408 409
Codepad
Buzzer
0 13 2 1 0 1
Default = Entry/Exit
Warning + Day
Alarm
Event
Code
Polarity Time
Base
Time Base
Multiplier
Event Codes
Event
Code
Description
Event
Code
Description
0 0
BOSCHSAT – Satellite Siren (Output 1 Only)
3 1
Dialler Disabled
0 1 System Armed 3 2 Dialler Active (On-Line)
0 2
System Disarmed
3 3
Ring Detect
0 3 Armed In STAY Mode 3 4 Codepad Panic (Multi-Break) V1.05+
0 4
Armed In AWAY
3 5
Mimic Zone 1
0 5
Pre-Arming Alert
3 6
Mimic Zone 2
0 6
Exit Warning (All Zones Sealed) + Entry Warning
3 7
Mimic Zone 3
0 7
Exit Warning
3 8
Mimic Zone 4
0 8 Exit Warning Finished 3 9 Mimic Zone 5
0 9
Kiss-Off After End Of Exit Time
3 10
Mimic Zone 6
0 10 Reserved 3 11 Mimic Zone 7
0 11
Entry Warning
3 12
Mimic Zone 8
0 12
Entry Warning + Day Alarm Resetting
3 13
Reserved
0 13
Exit Warning + Entry Warning + Day Alarm Resetting
3 14
Reserved
0 14
Day Alarm Resetting
3 15
Reserved
0 15 Day Alarm Latching 4 0 Reserved
1 0
Day Alarm Enabled
4 1
Reserved
1 1 Telephone Line Fail 4 2 Reserved
1 2
Kiss-Off Received
4 3
Reserved
1 3 Fuse Fail 4 4 Reserved
1 4
AC Fail
4 5
Chime
1 5
Low Battery
4 6
Zone Not Sealed
1 6
Horn Speaker Fail
4 7
Zone Not Sealed After Exit Time
1 7
Sensor Watch Alarm
4 8
Reserved
1 8 Codepad Medical Alarm 4 9 AC Mains Cycle (60 Hz Or 50 Hz)
1 9
Codepad Fire Alarm
4 10
Area 1 - Zone Unsealed (Solution 880 Only)
1 10 Codepad Panic Alarm 4 11 Area 2 – Zone Unsealed (Solution 880 Only)
1 11
Codepad Duress Alarm
4 12
Reserved
1 12
Access Denied (Code Retries)
4 13
Reserved
1 13
Reserved
4 14
Reserved
1 14
Horn Speaker (Output 1 Only)
4 15
Reserved
1 15 Sirens Running 5 0 Reserved
2 0
Strobe
5 1
Reserved
2 1 Silent Alarm 5 2 Area 1 In Alarm (Solution 880 Only)
2 2
Alarm In STAY Mode
5 3
Area 2 In Alarm (Solution 880 Only)
2 3
Alarm In AWAY Mode
5 4
Reserved
2 4
System Fault
5 5
Reserved
2 5
Fire Alarm (Resetting)
5 6
Area 1 Armed (Solution 880 Only)
2 6
Fire Alarm (Latching)
5 7
Area 2 Armed (Solution 880 Only)
2 7
Fire Alarm (Verification)
5 8
Reserved
2 8 Remote Control 1 5 9 Reserved
2 9
Remote Control 2
5 10
Area 1 Disarmed (Solution 880 Only)
2 10 Remote Control 3 5 11 Area 2 Disarmed (Solution 880 Only)
2 11
Radio Control Output 1
5 12
Reserved
2 12
Radio Control Output 2
5 13
Reserved
2 13
Radio Control Output 1 - Not In AWAY Mode
5 14
Any Areas Armed (Solution 880 Only)
2 14
Radio Control Output 2 - Not In AWAY Mode
5 15
Any Areas Disarmed (Solution 880 Only)
2 15 Communications Fail After 3 Attempts 6 0 Area 1 Codepad Data Terminal (Solution 880 Only)
3 0
Communications Fail
6 1
Area 2 Codepad Data Terminal (Solution 880 Only)