STAY Mode 2 Zones - Program
1. Enter the Installer Code or Master Code
followed by 8 and the # key.
[eg. 1234 + 4 + #].
2. Enter the Zone Number that you want the
system to automatically isolate followed by the
* key.
Repeat if more than one zone to be
automatically isolated when armed in STAY
Mode 2.
3.
Press the # key to exit.
Fault Analysis
1.
Press and hold the 5 key until two beeps are
heard.
2. Zone Indicators will display FAULT condition
(see table below).
3. Press # key to exit.
Zone
LED
FAULT Condition
Press and Hold Button 1
To Determine Fault
1
System Fault
1 = Battery Fail
2 = Date/Time
3 = RF Rx Jamming
RF Rx Tamper
RF Rx Comm’s Fail
4 = Horn Speaker Fail
5 = Telephone Line Fail
6 = E2 Fail
7 = Fuse Fail
8 = AC Fail
Press and Hold Button 2
To Determine Fault
2
RF Low Battery
Displays Zones (1 – 8) that
registers RF Low Battery
Press and Hold Button 3
To Determine Fault
3
Zone Tamper
Displays Zones (1 – 8) that
registers Zone Tamper
Press and Hold Button 4
To Determine Fault
4 Sensor Watch
Displays Zones (1 – 8) that
registers Zone Tamper
Press and Hold Button 5
To Determine Fault
5
RF Sensor Watch
Displays Zones (1 – 8) that
registers Zone Tamper
Press and Hold Button 6
To Determine Fault
6 Communication Fail
1 = Receiver 1 Fail (Dialler)
2 = Receiver 2 Fail (Dialler)
Modem Call (Alarm Link)
1.
Press and hold the 6 key until two beeps are
heard.
Latching Outputs (Reset)
1. Press and hold the 7 key until two beeps are
heard.
Codepad ID / Buzzer Tone
1. Press and hold the 8 key until the desired
buzzer tone has been reached.
If the system has been partitioned (CC488
Only), the Codepad will display a number to
identify which area the Codepad belongs to
(see table below).
2. Press the # key to exit.
Zone LED Codepad Assignment
1
Area 1
2
Area 2
7
Master Partitioned Codepad
Test Report
1.
Press and hold the 9 key until two beeps are
heard.
Speaker Test
1.
Press and hold the 1 key until two beeps are
heard. The speaker will sound for two
seconds.
Bell Test
1. Press and hold the 2 key until two beeps are
heard. The piezo will sound for two seconds.
Strobe Test (Toggle On/Off)
1. Press and hold the 3 key until three beeps are
heard to turn the strobe on.
2.
Press and hold the 3 key until two beeps are
heard to turn the strobe off.
Telco Arm Sequence (Call Forward On)
1. Enter your Installer Code or Master Code
followed by 3 and the # key.
[eg. 1234 + 3 + #].
2.
Press 1 followed by the # key.
3. Enter the Call Forward On sequence.
4. Press the # key to exit.
Telco Disarm Sequence (Call Forward On)
1. Enter your Installer Code or Master Code
followed by 3 and the # key.
[eg. 1234 + 3 + #].
2. Press 2 followed by the # key.
3.
Enter the Call Forward Off sequence.
4. Press the # key to exit.
Solution Ultima 880
Quick Reference Guide
7
Bosch Security Systems Pty Limited