Location 177
Dialler Options 1
Location 178
Dialler Options 2
Location 179
Dialler Options 3
Location 179
Dialler Options 3
(V1.04+)
Location 180
Alarm Link Options
Location 181 - 184
Installer Code
Location 185 - 264
User Codes
Location 185 - 188 189 Location 190 - 193 194 Location 195 - 198 199
User #01
2 5 8 0
10
User #02
15 15 15 15
2
User #03
15 15 15 15
2
Authority
Level
Authority
Level
Authority
Level
Location 200 - 203 204 Location 205 - 208 209 Location 210 - 213 214
User #04
15 15 15 15 2
User #05
15 15 15 15 2
User #06
15 15 15 15 2
Authority
Level
Authority
Level
Authority
Level
Location 215 - 218 219 Location 220 - 223 224 Location 225 - 228 229
User #07
15 15 15 15 2
User #08
0151515 3
RF User #09
15 15 15 15 2
Authority
Level
Authority
Level
Authority
Level
Location 230 - 233 234 Location 235 - 238 239 Location 240 - 243 244
RF User #10
15 15 15 15
2
RF User #11
15 15 15 15
2
RF User #12
15 15 15 15
2
Authority
Level
Authority
Level
Authority
Level
Location 245 - 248 249 Location 250 - 253 254 Location 255 - 258 259
RF User #13
15 15 15 15 2
RF User #14
15 15 15 15 2
RF User #15
15 15 15 15 2
Authority
Level
Authority
Level
Authority
Level
Location 260 - 263 264
RF User #16
15 15 15 15 2
Authority
Level
Authority
Level
Description
0
Arm/Disarm
1
Arm Only
2 Arm/Disarm + Open/Close Reports
3
Arm Only + Close Reports
4 Arm/Disarm + Code Required To Isolate
6
Arm/Disarm + Open/Close Reports + Code Required To Isolate
8
Master Code + Arm/Disarm
10
Master Code + Arm/Disarm + Open/Close Reports
12
Master Code + Arm/Disarm + Code Required To Isolate
14 Master Code + Arm/Disarm + Code Required To Isolate + Open/Close Reports
9
1 = Dialler Reporting Functions Allowed
2 = Remote Arming Via Telephone Allowed
4 = Answering Machine Bypass Only When Armed
8 = Use Bell 103 For FSK Format (Disabled = CCITT V21)
0
1 = Open/Close Reports Only If Previous Alarm
2 = Open/Close Reports For STAY Mode 1 and STAY Mode 2
4 = Delay Siren Until Transmission Complete
8 = Extend Handshake Wait Time From 30 To 55 Seconds
0
1 = Set DTMF Dialling Pulses To 1 Digit/Second
2 = Lockout Telephone Line Fail Alarm (V1.03+)
4 = Change Decadic Dialling To 60/40
8 = Reserved
2
1 = Set DTMF Dialling Pulses To 1 Digit/Second
2 = Lockout Telephone Line Fail Alarm (V1.03+)
4 = Change Decadic Dialling To 60/40
8 = External Modem Module (CC811) Required For FSK (V1.09+)
3
1 = Upload/Download Allowed
2 = Call Back Phone Number Required For Upload/Download
4 = Exit Upload/Download Connection On Alarm
8 = External Modem Module (CC811) Required For Alarm Link
1234
Solution Ultima 880
Quick Reference Guide
9
Bosch Security Systems Pty Limited