4.4 Worktop (optional)
Catch tappets are located on the rear right and left hand sides of the
worktop. To remove the worktop, press up the catch tappets, push the
worktop back and lift off.
4.5 NTC
The utilised temperature safety switch (>85 °C) is combined with the
NTC sensor. If a fault occurs, the heater is switched off at a water
temperature of 85 °C (operates in switching mode).
Temperature in °C Resistance in kW Tolerance +/– °C
25 48.4 7.9
30 38.5 7.1
50 16.5 6.2
60 11.0 5.6
65 9.1 5.5
58300000002393_ara_en_a.doc – 31.07.07 Seite 23 von 60