4.16 Detergent-solution pump
Remove the base panel and base plate; the detergent-solution pump
is locked in position at the front left side of the pump sump. To remove
the detergent-solution pump, disengage the lever (1), then rotate the
pump forwards (2). The pump can be removed by rotating it through
approx. one quarter of a revolution (3).
Technical specifications:
Nominal voltage 230–240 V
Frequency 50 Hz
Resistance 110–260 Ω
Delivery head 0.9 m
Conveying capacity 10 l / min
58300000002393_ara_en_a.doc – 31.07.07 Seite 34 von 60