4.15 Circulation pump
The circulation pump consists of a single-phase alternating current
motor.
Removal:
Remove the side panels and base plate, release the stainless steel
container / plastic base pan, consisting of 4 screws (front and back).
Place the container on its back and fold down the base module.
Note: Disconnect the level sensor housing from the base module.
The circulation pump is locked in position. Using a screwdriver, press
in the catch on the right side of the circulation pump and rotate the
pump in a clockwise direction. The pump can then be removed.
Installation is in reverse sequence. Prior to installation, lubricate the
seal with washing-up liquid.
Technical specifications:
Rated voltage 230–240 V
Frequency 50 Hz
Resistance Ha approx. 80 Ω
HI 1 approx. 85 Ω
HI 2 approx. 13 Ω
Delivery head 3.1 m
Conveying capacity 60 l / min
58300000002393_ara_en_a.doc – 31.07.07 Seite 33 von 60