Parking Lot Sensor TPS110 EU
6 | 14
Installation of the sensor base
Insert the adhesive cartridge into the glue gun/adhesive press (Fig. 7 Inserting the adhesive cartridge; in the case of
DELO®-PUR 9692, the mixing ratio is 1:1, so you do not have to pay attention to the orientation of the cartridge). Then
attach the mixing tip on the cartridge by removing the cartridge cap (Fig. 8 Sealing cap adhesive cartridge) and
attaching the mixing tube (Fig. 9 Mixing tube on adhesive cartridge; here, bayonet fitting).
Figure 7 Inserting the cartridge Figure 8 Sealing cap Figure 9 Mixing tube
To avoid contamination and to get the maximum use out of the plasma cleaning process, open the sensor base
package just before applying the adhesive. Apply about 40 ml of the DELO-PUR 9692 adhesive in the center (see Fig.
10 Adhesive application and Fig. 11 Adhesive amount). If you use a 50 ml cartridge, you can empty it completely.
Apply the adhesive in the form of a bubble in the center of the sensor base (no screws or even surface).
INFORMATION:
The use of the mixing tube is important for mixing the two components of the adhesive and for the
resulting adhesive effect.