en Cleaning and maintenance
44
3. Clean the drain hose and siphon
connecting piece.
4. Re-attach the drain hose and secure
the connection point using the hose
clamp.
Filter in the water supply is
blocked
Release water pressure in the supply
hose:
1. Turn off the water tap.
2. Select the Cottons i (activate
G SpeedPerfect setting)
programme.
Note: If your appliance with
intelligent dosing system
*
, you also
need to deactivate the intelligent
dosing system.
3. Select the Start/Reload A button.
Allow the programme to run for
approx. 40 seconds.
4. Turn the programme selector to Off.
5. Pull out the mains plug.
Clean the filters:
1. Disconnect the hose from the rear of
the appliance.
2. Use pliers to remove the filter.
3. Clean the filter with a small brush.
4. Connect the hose and check for
leaks.