Settings in the service menu
Worcester 2000 – 6 721 814 551 (2019/09)
46
8.2 Service functions overview
8.2.1 Menu 1
Press the ( key and * key at the same time until L.1 appears.
To confirm the selection: press OK key.
Selecting and setting the service function.
Table 21 Menu 1: display of information
8.2.2 Menu 2
Press the ( key and * key at the same time until L.1 appears.
Press arrow key until L.2 is displayed.
To confirm the selection: press OK key.
Selecting and setting the service function.
The basic settings are depicted as highlighted in the following table.
Table 22 Menu 2: hydraulic settings
Service function Unit Further information
1-A1 Current operating status Status code, Section 11.2
1-A2 Current fault Error code, Section 11.2
1-A3 Upper limit of the maximum heat output % The maximum heat output can be decreased via the service function
3-b1.
1-A4 Upper limit of the maximum DHW output % The maximum DHW output can be decreased via the service
function 3-C1.
1-A5 Temperature at flow temperature sensor °C
1-A6 Set flow temperature °C
1-b2 Current turbine flow rate l/min
1-b3 Current DHW temperature °C
1-b4 Current DHW outlet temperature °C
1-b5 Current temperature at the cylinder °C
1-b7 Set DHW temperature °C
1-b8 Current thermal output as a % of the maximum rated heat output
in heating mode
% During DHW heating, values greater than 100 % may be displayed.
1-C1 Ionisation current A While the burner is operating: ≥ 2 A = OK, < 2 A = faulty
While the burner is switched off: < 2 A = OK, ≥ 2 A = faulty
1-C2 Current pump output as % of rated pump output
1-C4 Current outside temperature with outside temperature sensor
connected
°C
1-C5 Temperature at the solar buffer cylinder °C Only displayed when a solar module is connected.
1-C6 Operating pressure bar
1-d1 Collector temperature °C Only displayed when a solar module is connected.
1-d2 Temperature at the solar buffer cylinder (bottom) °C Only displayed when a solar module is connected.
1-d3 Solar pump % Only displayed when a solar module is connected.
1-d4 Solar unit fault Only displayed when a solar module is connected.
Error code
1-E1 Software version of the control panel (main version)
1-E2 Software version of the control panel (secondary version)
1-E3 Coding plug number
1-E4 Coding plug version
1-EA Software version of device electronics (main version)
1-Eb Software version of device electronics (secondary version)
Service function Settings/adjustment range Remark/restriction
2-A1 Low-loss header 0: no low loss header installed
1: (not available)
2: low loss header connected to the module
This setting defines where the sensor of the low
loss header is connected.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Worcester 2000 Series and is the answer not in the manual?

Bosch Worcester 2000 Series Specifications

General IconGeneral
BrandBosch
ModelWorcester 2000 Series
CategoryBoiler
LanguageEnglish

Related product manuals