13.5 Setting values for output
The maximum rated heat output can be reduced to up to 50 % of the
output range (service function 3-b1).
The minimum rated heat output can be increased to up to 50 % of the
output range (service function 5-A3).
13.5.1 Gas setting values
GC2000iW 25 C
Table 38 GC2000iW 25 C
GC2000iW 30 C
Table 39 GC2000iW 30 C
Display
percentage %
Heat Output
[kW]
Heat input
[kW]
Gas flow rate [l/min]
80 20.0 20.40 35.0
75 18.7 19.13 32.8
70 17.5 17.85 30.6
65 16.2 16.58 28.4
60 15.0 15.30 26.3
55 13.7 14.03 24.1
50 12.5 12.75 21.9
45 11.2 11.48 19.7
40 10.0 10.20 17.5
35 8.7 8.93 15.3
30 7.5 7.65 13.1
25 6.2 6.38 10.9
20 5.0 5.10 8.8
19 4.8 4.92 8.4
Display
percentage %
Heat Output
[kW]
Heat input
[kW]
Gas flow rate [l/min]
68 20.0 20.4 35.0
65 19.1 19.5 33.5
60 17.6 18.0 30.9
55 16.2 16.5 28.3
50 14.7 15.0 25.7
45 13.2 13.5 23.2
40 11.7 12.0 20.6
35 10.3 10.5 18.0
30 8.8 9.0 15.4
25 7.3 7.5 12.9
20 5.9 6.0 10.3
16 4.8 4.92 8.4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Worcester 2000 Series and is the answer not in the manual?

Bosch Worcester 2000 Series Specifications

General IconGeneral
BrandBosch
ModelWorcester 2000 Series
CategoryBoiler
LanguageEnglish

Related product manuals