Settings in the service menu
49
Worcester 2000 – 6 721 814 551 (2019/09)
Table 24 Menu 4: settings
8.2.5 Menu 5
Press the ( key and * key at the same time, until L.A is displayed.
Keep pressing the arrow key , until L.5 is displayed.
To confirm the selection: Press the OK key.
Select and set the service function.
The basic settings are depicted as highlighted in the following table.
These settings will not be reset during a factory reset.
Table 25 Menu 5: Limit values
4-b5 Device frost protection OFF: switched off
ON: switched on
This service function is only available if service
function 4-b1 is activated.
The device frost protection function switches the
burner and heating pump on when the outside
temperature falls below 5 °C. This prevents the
wall mounted boiler freezing.
4-b6 Temperature value for the system frost
protection
0 ... 5 ... 10 °C This service function is only available if the frost
protection function (service function 4-b1) was
activated.
If the outside temperature does not exceed the
frost threshold temperature, then the heating
pump in the heating circuit switches on (system
frost protection).
4-E1 LCD backlighting OFF: backlighting switches off 2 minutes after
the last time a key was pressed
ON: backlighting permanently on
4-E2 Unit of temperature °C
• °F
4-F1 Reset device to basic setting YES: device is reset to factory settings
4-F2 Reset the fault display NO: fault is retained
YES: fault is reset
Service function Settings/adjustment range Remark/restriction
Service function L.5 Settings/adjustment range Remark/restriction
5-A1 Maximum flow temperature 30 … 82 °C Limits the adjustment range for the flow
temperature.
5-A2 Maximum DHW temperature 35...60 ... 80 °C Limits the adjustment range for the hot water (not
applicable on combination appliances.).
5-A3 Minimum boiler output (heating and
DHW)
GC2000iW 25 C : 19 ... 49%
GC2000iW 30 C : 16 ... 49%
Minimum heat output.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Worcester 2000 Series and is the answer not in the manual?

Bosch Worcester 2000 Series Specifications

General IconGeneral
BrandBosch
ModelWorcester 2000 Series
CategoryBoiler
LanguageEnglish

Related product manuals