4848
Greenstar combi boiler range
vertical fl uing options
The Greenstar combi boiler range offers the choice of
2 differently sized vertical RSF fl ue systems, 100mm and
125mm. Both systems have different maximum lengths.
The following diagrams detail the permissible lengths.
Vertical RSF fl ue
100mm dia. vertical balanced fl ue kit
1 x fl ue terminal assembly
1 x weather sealing collar
1 x fi re stop spacer
1 x vertical adaptor
Part No. 7 719 002 430
125mm dia. vertical balanced fl ue kit
1 x fl ue terminal assembly
1 x weather sealing collar
1 x fi re stop spacer
1 x vertical adaptor
Part No. 7 719 002 431
Accessories
Components Part No. Description
100mm diameter
7 719 002 430
Vertical 1,090mm balanced
ue kit (inc. adaptor)
7 716 191 083 Extension fl ue kit (960mm*)
7 716 191 172 2m fl ue extension
7 716 191 133 Short fl ue extension (220mm*)
7 716 191 084 90º bend
7 716 191 085 45º bend
7 716 191 090 Flashing – fl at roof
7 716 191 091 Flashing – pitched roof
*Dimensions when fi tted
125mm diameter
7 719 002 431
Vertical 1,365mm balanced
ue kit (inc. adaptor)
7 719 003 666 Extension fl ue kit (960mm*)
7 719 003 664 90º bend
7 719 003 665 45º bend
7 716 191 090 Flashing – fl at roof
7 716 191 091 Flashing – pitched roof
*Dimensions when fi tted
Flue diameter 100mm 125mm
Greenstar CDi Classic series
Minimum fl ue length 1,090mm 1,365mm
Maximum fl ue length
(inc. adaptor)
29CDi Classic
9,400mm 18,500mm
34CDi Classic 8,000mm 16,000mm
38CDi Classic 7,500mm 16,000mm
42CDi Classic 7,500mm 16,000mm
Greenstar CDi Compact and Si Compact series
Minimum fl ue length 1,090mm 1,365mm
Maximum fl ue length
(inc. adaptor) 6,000mm 15,000mm
Greenstar i Junior series
Minimum fl ue length 1,090mm 1,365mm
Maximum fl ue length
(inc. adaptor) 6,400mm 15,000mm
The following criteria should be noted when planning
the installation:
Because the appliance operates at high effi ciency, a
white plume of condensation will be emitted from the
terminal. Care must be taken when selecting the fl ue
terminal position
To achieve a maximum fl ue length, one of the extension
ue kits will need to be cut so that the permitted
maximum fl ue length is not exceeded
Vertical fl ue options 1-4 illustrate common fl ue
installations. Other confi gurations of the fl ue system are
possible up to, and not exceeding, the stated maximum
ue lengths.