APPLIANCE INFORMATION
6 720 815 724 (2015/11) 9
2.4 Product data on energy consumption
The following product data satisfy the requirements of the EU Regulations No. 811/2013, No. 812/2013, No. 813/2013 and No. 814/2013
supplementing Directive 2010/30/EU.
Product data Symbol Unit 7 738 100 244 7 738 100 233 7 738 100 236 7 738 100 237
Product type – – 30CDi Classic
System
ErP
30CDi Classic
System
ErP
LPG
35CDi Classic
System
ErP
35CDi Classic
System
ErP
LPG
Condensing boiler – – Yes Yes Yes Yes
Rated heat output P
rated
kW 30 30 34 34
Seasonal space heating energy efficiency
s
%92 92 92 92
Energy efficiency class – –A AA A
Useful heat output
At rated heat output and high temperature regime
1)
1) High temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
P
4
kW 30.0 30.0 34.0 34.0
At 30 % of rated heat output and low temperature regime
2)
2) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
P
1
kW 10.0 10.0 11.4 11.4
Useful efficiency
At rated heat output and high temperature regime
1)
4
% 88.2 88.2 88.2 88.2
At 30 % of rated heat output and low temperature regime
2)
1
% 97.5 97.5 97.5 97.5
Auxiliary electricity consumption
At full load el
max
kW 0.058 0.058 0.058 0.058
At part load el
min
kW 0.030 0.030 0.030 0.030
In standby mode P
SB
kW 0.004 0.004 0.004 0.004
Other items
Standby heat loss P
stby
kW 0.048 0.048 0.048 0.048
Emissions of nitrogen oxides NOx mg/kWh 30 30 30 30
Sound power level, indoors L
WA
dB(A) 55 55 58 58
Table 9 Product data for energy consumption