Page 17 from 43 6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
Pict.21 Thermal Fuse detail
4.7 Water Inlet Assy
The inlet water valve contains the water connection of ¾” that integrates also the filter and
the flow restrictor according country characteristics.
Flow rate valve / Filter
The inlet water valve contains the filter and is acessible removing screw nº1 and pulling out the
valve with know nº2.
Pict.22 Inlet flow restrictor with filter
4.8 Water temperature sensors
The outlet and inlet water temperature is measured by a 8.5 kΩ NTC (outlet) and 50 kΩ
NTC (inlet). Both NTC measures temperature and are connected to different cable colors
and connectors in the control unit.
Pict.23 Cold / Hot Temperature sensor