4.9 Box Temperature sensor
The Box air temperature is measured by a 10 kΩ NTC (See table with characteristic
values) and is assembled inside the room sealed box, in order to monitor the temperature
inside of the cabinet.
Pict.24 – Box air temperature sensor
4.10 Water Flow Sensor
Water flow is measured by a turbine flow sensor that is fed by a DC signal of 5 V, and
gives a proportional feedback to the measured water flow.
- Flow rate to operate the appliance: 2.8 l/min
- Flow rate to shut off the appliance: 2.4 l/min
Water flow characteristic curve formula: f = 6.9 x Q
Note:
f is output frequency (Hz)
Q is water flow rate (L/min)