EasyManua.ls Logo

Bosch WTD 12-4 AME 23 - Box Temperature Sensor; Water Flow Sensor

Bosch WTD 12-4 AME 23
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 18 from 43 6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
4.9 Box Temperature sensor
The Box air temperature is measured by a 10 kΩ NTC (See table with characteristic
values) and is assembled inside the room sealed box, in order to monitor the temperature
inside of the cabinet.
Pict.24 Box air temperature sensor
4.10 Water Flow Sensor
Water flow is measured by a turbine flow sensor that is fed by a DC signal of 5 V, and
gives a proportional feedback to the measured water flow.
- Flow rate to operate the appliance: 2.8 l/min
- Flow rate to shut off the appliance: 2.4 l/min
Water flow characteristic curve formula f = 6.9 x Q
Note:
f is output frequency (Hz)
Q is water flow rate (L/min)
Flow (L/min)
Frequency (Hz
15
103.5
14
96.6
13
89.7
12
82.8
11
75.9
10
69
9
62.1
8
55.2
7
48.3
6
41.4
5
34.5
4
27.6
3
20.7
2
13.8
Table 8 Water flow sensor values