EasyManua.ls Logo

Bosch WTD 15-4 AME 23 - Page 10

Bosch WTD 15-4 AME 23
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 10 from 43 6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
Pict.10 Control Panel HMI Overview T5600-T5700
On / Off button
The main switch is assembled on the PCB and disconnects the
unit so no voltage at components is present although anti-freeze
kit keeps active due to temperatures checks even in Off mode.
Menu Button
- Used to Enter in service mode to access service parameters
which can be used by the user, installer, technician
Program Button
- Used to Scroll back in the service mode menu when navigating
menus
OK Button
- Save value or adjust set values
- Save a temperature setting (user)
Selection button
Used to scroll inside menu ensuring navigation on parameters
inside the diagnostic mode
Table 6 Control Panel Buttons
Symbol
Description
Observation
Temperature Unit:
ºC default value
ºF alternative value
Selection can be done by
changing default value on
service mode (P6) inside SA
(settings) parameter