EasyManua.ls Logo

Bosch WTD 15-4 AME 23 - 5 Working Principle; Electric Measurements

Bosch WTD 15-4 AME 23
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 21 from 43 6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
Pict.27 Ionization electrode and its sealing element
Pict.28 Ignition electrodes position on the burner
5. Working Principle / Electric Measurements
Water Flow Detection and solar mode operation
Water Flow Calculation
procedure
WF = Power
(T
set
T
in
)
WF ≥ 2.8 l/min
Burner ON
WF < 2.4 l/min
Burner OFF
Burner On
Solar mode Operation
Burner Off
T
in
T
set
1K
T
out
< 60ºC
(if T
set
≤ 50ºC)
or
T
out
< T
set
+
10ºC
(if T
set
> 50ºC)

Other manuals for Bosch WTD 15-4 AME 23