Page 16 from 43 6 720 887 547 “SM FP_ErP MPP Europe 2018/08 en”
Pict.18 Heat exchanger
For its protection and ensuring maximum life time, there is over-heating protection ensured by a
bimetallic thermostat in direct contact with the copper and one thermal fuse around the heat
exchanger.
Pict.19 Temperature limiter (activation at 85ºC)
The thermal fuse is located around the heat exchanger and for protection is insulated,
nevertheless is composed by 4 specific fuses that melt at 192 ºC in the event of an overheating.
Pict.20 Thermal Fuse with / without insulation