60
P12-P15-P18
10 Settings and Optimum Operating Values
P12
P15
Distillation:
Cooling water regulator condenser
°C(°F)
45(113)
45(113)
Thermal sensor:
Cycle distillation OFF
°C(°F)
135(275)
135(275)
Still stripping OFF
°C(°F)
138(280)
138(280)
Still stripping OFF (electric)
°C(°F)
145(293)
145(293)
Thermal sensor, distilled solvent
°C(°F)
55(131)
55(131)
Panel in steam feeder
mm(in)
4(0.16)
4(0.16)
Panel in direct steam line
mm(in)
3(0.12)
3(0.12)
Water filling capacity in heating chamber, approx.
l(US gal)
5(1.3)
5(1.3)
Pressure control switch, still (el):
ON
bar(psi)
5.2(75.4)
5.2(75.4)
OFF
bar(psi)
5.6(81.2)
5.6(81.2)
Safety thermostat, heating rod (elec. Only)
°C(°F)
230(446)
230(446)