61
P12-P15-P18
10 Settings and Optimum Operating Values
10
P18
Basic value:
Steam pressure (saturated steam)
bar(psi)
45(5872.5)
Steam temperature (max. permitted)
°C(°F)
150(302)
Cooling water pressure
bar(psi)
2-4(29-58)
Cooling water temperature, max.
°C(°F)
25(77)
Compressed air
bar(psi)
6(87)
Cage speeds:
Cleaning/
RPM
35
Spinning
RPM
500
Reversing cycle (cleaning)
sec.
10/1/10
Low level
l(US gal)
45(11.9)
High level
l(US gal)
90(23.7)
Pump pressure (max.)
bar(psi)
2.5(36.2)
Filter surface, economy filter
m
2
(ft
2
)
2.7(29.0)
Filter powder (only for machines without emission-
free still rake out system)
kg(lb)
1.2(2.6)
Tank I: optimum filling volume (high level)
l(US gal)
90(23.7)
Tank III: optimum filling volume
l(US gal)
90(23.7)
Detergent solution cooler:
Detergent solution thermal sensor:
Detergent solution cooler ON
°C(°F)
1530(59-86)
Refrigeration technology:
Filling capacity, cooling agent R 404A
kg(lb)
4.6(10.1)
Nozzle size: solvent cooling
no.
03
Drying + Reduction
no.
06
High pressure control switch ON approx.
bar(psi)
21(319)
High pressure control switch OFF approx.
bar(psi)
26(377)
Low pressure control approx.
bar(psi)
1(14.5)
Drying:
Cooling water regulator setting:
Adjust 4 6 min. after start of drying
bar(psi)
20(290)
Temperature sensor, cage entry (gentle drying)
°C(°F)
60(140)
Temperature sensor, cage exit
°C(°F)
50(122)
Temperature sensor after cooler:
Control value, drying
°C(°F)
40(104)
Control value, cycle end
°C(°F)
15(59)
Safety thermostat, heater battery (electric only)
°C(°F)
110(230)