5.1.4 Machine Environment
Do not operate systems with open flames, such as gas-heated flatwork
ironers or tumblers, in the same room because poisonous, corrosive gases
could result from the solvent decomposition.
No surfaces with a temperature of more than 140° C (284° F) are permitted in the machine
room.
You must ensure that the air from the machine room cannot escape into a heating room, if
there is one in the area.
The air from the machine room is not permitted to be fed into the exhaust line of a furnace
system.