33
8 Important Information 8
To fill without emissions, proceed as follows:
- Remove the screw cap on the pump line.
- Connect a hose between the barrel and pump suction side.
- Connect a gas displacement line between the barrel and water separator.
- Open the ball valve.
- Start program P44.
- The tanks fill up, with one overflowing into the other.
- Watch the level of the liquid in the tanks and stop program P44 when the tanks are full.
- Close the ball valve.
- Remove the connecting lines to the barrel.
- Screw the cap back on to the pump line.
- Remove the gas displacement line.
On c and o combinations:
- First fill the c machine with P44
- Next start P61 on the o machine in order to fill it.
- Then start P44 on the c machine again.
8.1.3 Refilling Solvent
Follow the procedure given in Point 8.1.2 for routine refilling of solvent.
Attention: Even empty containers can still hold solvent residues.
Therefore tightly seal the container (barrel) again and
store or dispose of in accordance with regulations!
P25/P30